Skills

Comp3 Packed Decimal

Reference for COBOL COMP-3 (packed decimal / BCD) numeric storage -- layout on disk...

Install

npx skills add benchflow-ai/skillsbench --skill comp3-packed-decimal -g -a claude-code -y
Category
Engineering
Updated
12d ago
License
Apache-2.0
Context cost
Lightabout 971 tokens
Runs scripts
No, instructions only

What it does

Reference for COBOL COMP-3 (packed decimal / BCD) numeric storage -- layout on disk, declaring it in the FD, and pitfalls when carrying the decoded value through working storage and into later arithmetic. Useful when an input record holds a balance, rate, or carry-forward as packed decimal rather than a printable digit string.

COMP-3 / packed decimal storage

USAGE COMP-3 (a.k.a. PACKED-DECIMAL) stores a signed numeric field as binary-coded-decimal nibbles: each byte holds two decimal digits, except the last byte whose low nibble is the sign:

PIC S9(11)V99 USAGE COMP-3
+--+--+--+--+--+--+--+
|D1|D2|D3|D4|D5|D6|D7|   7 bytes total for 13 digits
+--+--+--+--+--+--+--+
              ^^-- sign nibble in the LOW half of the last byte

Bytes-on-disk = ceil((digit_count + 1) / 2). For PIC S9(11)V99 that is ceil(14 / 2) = 7 bytes. The high nibble of the first byte holds the first decimal digit; the implied decimal point is not stored.

Sign nibbles:

NibbleMeaning
Cpositive (some shops emit F for unsigned, but C is standard for SIGNED)
Dnegative
Funsigned / non-S PIC

Declaring COMP-3 in an FD

The record layout must match the byte budget. If the data in the file is packed but you declare the field as PIC X(n) or as an unpacked decimal, the COBOL runtime will not decode it and the value will look like binary garbage when displayed.

FD  MAST-FILE
    RECORD CONTAINS 80 CHARACTERS.
01  MAST-REC.
    05  M-ACCT     PIC X(6).
    05  M-TYPE     PIC X.
    05  M-STATUS   PIC X.
    05  M-CCY      PIC X(3).
    05  M-CARRY    PIC S9(11)V99 USAGE COMP-3.   *> 7 bytes
    05  FILLER     PIC X(62).                    *> remainder of 80

Use a runtime check: cobc -x -free -o prog PROG.cbl && ./prog and DISPLAY one record's COMP-3 field before relying on it. Common mistakes:

  • Forgetting the USAGE COMP-3 clause -> the field is read as 7 zoned ASCII characters; values look like control characters.
  • Wrong digit count -> the byte budget changes and subsequent fields slide.
  • Moving COMP-3 directly into a PIC X(7) workspace -> the bytes copy but no arithmetic translation happens; the value is unusable.

Carrying the value through working storage

Read the whole SKILL.md on GitHub

More in Engineering